"BINTEX" 3 CORE FLAT CABLE XLPE INSULATION COPPER COND.
Current Carrying Capacity (amp)
Sr.No. Size PVC Insulation XLPE Insulation
1 2.50 Sq. mm. 18 amp. 30 amp
2 4.00 Sq. mm. 26 amp 37 amp
3 6.00 Sq. mm. 31 amp 46 amp
4 10.0 Sq. mm. 42 amp 66 amp
5 16.00 Sq. mm. 57 amp 72 amp
6 25.0 Sq. mm. 72 amp 113 amp
7 35.0 Sq. mm. 90 amp 139 amp

 

"BINTEX" flat submersible cable manufactured with pure 99.98% electronic bare copper wire. Bunched Copper conductor insulation with red,yellow and blue colour with thermostat type CROSS POLYLINK POLYTHENE (XLPE) uniform thickness in core insulation in advanced machinery. The Gray color sheath with uniform thickness of heat and moisture resistant type PVC (Grade ST-2) compound. the cables are available with brand name, Size, voltage and sequential meter marking on the sheath.

Benefit of XLPE Insulation:-

1)   Continuous conductor temperature of insulated cables is 90c as against  70c in PVC Insulated cables hence it is possible to use one size lower than PVC for the same current.

2)   In XLPE insulated cables overload capacity is 130c as against 120c in PVC insulated cables.

3)   In XLPE insulated cables short circuit ratting 250c as against 130c in PVC cables.

4)   XLPE density is lower than PVC which makes them lighter in weight hence the bending radius is smaller than PVC.

5)   Lower Di-electric constant and power factor is saving in power losses which means saving in costs.

6)  There is no need of any special technique in jointing of cables.

7)  This cable has long and  trouble free life and are ideally suitable for submersible pump. 

 

All information given herein is in good faith. Bintex shall not be liable for any damages arising out of incorrect use or interpretation.

The company reserves the right to change any of the above specifications without any prior notice.

 

3 CORE PVC FLAT CABLES

 

"BINTEX" 3 core flat cables are manufactured with bright annealed proper bunched electrolytic grade copper which ensures flexibility  and resistance. We have in-house facility for manufacturing copper wire as per requirement. Each copper conductor is insulated with red, yellow and blue colour. The black color outer sheath is made from special grade pvc with sequential meter marking, brand name, size and voltage. Bintex cables are performing better in difficult condition.

 

3 Core Flat Cables as per Is 694:1990 with ISI mark
Conductor insulation Sheath Overall Dimensions
Area
Sq.
mm.
No/Dia.
of Strands
mm
Thickness
(Nom)
mm
Thickness
(Nom)
mm
Width
(Approx)
'W' mm
Hight
(Aprox)
'H'mm
Conductor
Resistance
@ 20 0c
(Max)
ohms/km.
Current
Carrying
Capacity
@40 0C
Amps
1.5 22/0.30* 0.6 0.9 10.30 4.9 12.10 14
2.5 36/0.30* 0.7 1.0 12.60 5.8 7.41 18
4.0 56.030** 0.8 1.0 14.80 6.6 4.95 26

Note:
The strand diameter is nominal. However, construction of conductor is designed to satisfy the requirements of conductor resistance as per IS 8130:1984.
* As per Conductor Class 2 of IS 8130:1984
** As per conductor class 5 of IS 8130:1984

 

3 Core Flat Cables Generally Conforming to IS 694:1990
Conductor insulation Sheath Overall Dimensions
Area
Sq.
mm.
No/Dia.
of Strands
mm
Thickness
(Nom)
mm
Thickness
(Nom)
mm
Width
(Approx)
'W' mm
Hight
(Aprox)
'H'mm
Conductor
Resistance
@ 20 0c
(Max)
ohms/km.
Current
Carrying
Capacity
@40 0C
Amps
6.0 84/0.30 0.8 1.15 16.50 7.40 3.30 31
10.0 140/0.30 1.0 1.40 21.00 9.25 1.91 42
16.0 226/0.30 1.0 1.40 24.50 10.70 1.21 57
25.0 354/0.30 1.2 2.00 30.60 13.50 0.780 72
30.5 495/0.30 1.2 2.00 34.40 14.70 0.554 90
50.0 703/0.30 1.4 2.20 41.20 17.20 0.386 115
70.0 360/0.50 1.4 2.20 46.60 19.00 0.272 143
95.0 475/0.50 1.6 2.40 53.00 21.40 0.2066 165

NOTE:

The Number of wires and strand diameter will be such as to satisfy the requirements of conductor resistance as per IS 8130:1984

SELECTION GUIDE FOR 3 CORE FLAT CABLES
1) HP Vs. Current :The Full load current for submersible pump motors, 3 phase, 50 cycles, 415- 425 V.
HP
Amp
5.0 7.5 10.0 12.5 15.5 17.5 20.0 25.0 30.0 35.0 40.0 45.0 50.0 55.0 60.0 65.0 70.0 75.0 80.0
7.0 11.0 14.9 18.9 22.5 25.2 28.4 35.6 42.3 50.4 58.1 62.1 67.5 73.8 81.0 87.3 93.6 100.8 108.0
2) Derating Factors : Multiply the current carrying of the cables by factors given below for various ambient temperatures.
Ambient Temperature OC
Rating Factor
30 35 40 45 50
1.09 1.04 1.00 0.95 0.77